NOTE: THESE INSTRUCTIONS SHOULD BE LEFT
WITH THE APPLIANCE AND THE USER TO RETAIN
FOR FUTURE REFERENCE.
Aga Gas Fired ranges are delivered unassembled.
Before installation can be made the site is inspected for
suitability by an Authorised Aga Distributor and corrected
where necessary to conform with local installation codes
or in the absence of local codes with:
In Canada:
The CAN/CGA-B149 installation codes.
In U.S.:
The National Fuel Gas Code ANSI Z223. 1-latest edition.
Assembly is undertaken on site by the same Aga
Distributor to ensure correct performance and safety.
It is essential that the base or hearth on which the range
stands should be level and strong enough to support the
weight of the range.
Approximate weights:-
Models GC (Open Flue) and GC (Direct Vent)
- 408kg (900lb)
Models GE (Open Flue) and GC (Direct Vent)
- 585kg (1290lb)
The top face of the hearth must be of non-combustible
material for a minimum thickness of 12mm (1/2in) and
comply with current Building Regulations and National
Fire Laws.
The wall behind the cooker draft hood and flue connector
must have a minimum air gap of 57mm (2 1/4”). Any
openings in the wall behind the range or in the floor under
the range must be sealed before appliance installation.
Ensure the draft hood is securely bolted to the support
spigot as shown in Fig. 2.
NOTE: THIS IS NORMALLY FITTED AND SECURED BY
THE FACTORY BEFORE DESPATCH.
The wall behind the range must be the outside wall for
the venting of flue products. Wall thickness between
150mm (6 in) and 355mm (14 in) can be catered for at the
same time as site inspection.
Alternatively, special lengths can be offered to order up to
a maximum of 610mm (24 in) long.
Open Flue - Models GC and GE
Installation Instructions for Aga Gas Fired Range
Models: GC Open Flue Range (2 Oven)
GC Direct Vent Range (2 Oven)
GE Open Flue Range (4 Oven)
GE Direct Vent Range (4 Oven)
For U.S. and Canadian Markets
1 04/08 EINS 33644
BASE OR HEARTH
OPEN FLUE RANGE -
MODELS GC AND GE
DIRECT VENT RANGE-
MODELS GC AND GE
Zobrazit stránku 0
1 2 3 4 5 6 7 8

Shrnutí obsahu

Strany 1

NOTE: THESE INSTRUCTIONS SHOULD BE LEFTWITH THE APPLIANCE AND THE USER TO RETAINFOR FUTURE REFERENCE.Aga Gas Fired ranges are delivered unassembled.Be

Strany 2 - VENT CONNECTION

2A 100mm (4in) Type B Gas Vent must be used and fastenedby screw to the draft hood flue collar.U.S.The gas vent must be connected to a chimney orindep

Strany 3 - WALL TILING

3the appliance and should not be less than (4in) internal diameter.7. In the event of an extractor fan being fitted in the vicinity ofthe range, compe

Strany 4 - LOCATION OF NAME PLATE

GC, GE Open Flue ModelsMaximum Heat Input: 4.4kw (15,000 (Btu/h)GC, GE Direct Vent ModelsThe appliance and its individual shut-off valve must bediscon

Strany 5 - INITIAL LIGHTING OF RANGE

In a cold range, difficulty may be experienced in maintainingthe main burner alight on initial light-up only. Should thisoccur, set the control knob t

Strany 6 - TECHNICAL SPECIFICATION

NOTE: DO NOT ATTEMPT TO SERVICE THE RANGEYOURSELF. CONTACT YOUR LOCAL AGA DISTRIBUTORSTATING THE MODEL AND SERIAL NUMBER TOGETHERWITH YOUR NAME AND AD

Strany 7

7Fig. 12 Pilot/Thermocouple DESN 512827

Strany 8 - YEARLY SERVICE

It is recommended that the range be serviced at regular annualintervals.Arrange with the householder that the range has been turnedOFF the night befor